SLQ-Double-Oil-Grease-Filter

Product: SLQ Double Oil Grease Filter
Products Advantage:
1. Max. operation 6bar
2. Filtering area from 0.082cm2 ~3.30 cm2
3. Double tank for cycle filtering 24Hs working available

SLQ Double oil grease filter is suitable for the nominal pressure of 0.6MP in the oil lubrication system, with the removal of impurities in the lubricating oil to the lubrication point of the oil to achieve the clean function, small for the whole, the larger for the combination, respectively, by the two group filter cartridge and a three-way six-way valve composition, work a tube work, a tube backup, can be achieved without switching switch filter cartridge to achieve the purpose of continuous lubrication system.

SLQ Double Oil Grease Filter Working Principle:

  1. SLQ Double oil grease filter consists of a six-way valve and two groups of filter devices, placed in the pump outlet and cooler front, normal work, a group of filter device and the other group is closed by the valve as stand-by application.
  2. The valve-type six-way valve is the manual operation while the work process, cut off the standby filter device connected to the work of the filter device, the upper part of the valve, only the mark, in the work for pressure ≤ 6kgf / cm2 can be non-stop commutation.
  3. The filter device is designed as the two groups, a group of work, other is as spare part. In the work of the filter device needs to be cleaned when cleaning, you can start another set of spare filter device, without affecting the normal work of the host.
  4. The symbol of SLQ double oil grease filter:SLQ-Double-Oil-Grease-Filter-symbol

Instructions For Using Of SLQ Double Oil Grease Filter:

1. When the filter inlet and outlet pressure difference ≥ 0.5kgf / cm2, indicating that the filter device has been blocked by mechanical impurities, should be promptly cleaned or replace the filter, the filter cylinder should also be cleaned.
2. In the normal work of the filter, the difference pressure of inlet and outlet port should be ≤ 0.035mpa.

Ordering Code Of SLQ Oil Grease Filter Series

HS-SLQ40*
(1)(2)(3)(4)

(1) HS = By Hudsun Industry
(2) SLQ = SLQ Double Oil Grease Filter series
(3) Filter Size (See the chart below)
(4) For Further Information

SLQ Double Oil Grease Filter Technical Data

ModelSize
DN
(mm)
Max.
Pressure
Filter
Area
(m2)
Kinematic Viscosity (cSt)Weight
(kg)
28466789326
Filter Fineness (mm)
0.080.120.080.120.080.120.080.120.080.12
Filter Fineness (mm)
SLQ-32320.6MPa0.0821303101202126316128.568.718.748.881.7
SLQ-40400.2133079030554016038472.317548125115
SLQ-50500.314851160447793250565106.525669160203.8
SLQ-65650.5282019607601340400955180434106250288
SLQ-80800.83313203100120021506301533288695170400346
SLQ-1001001.311990475018403230100023104361050267630468
SLQ-1251252.20334080003100542016803890730177045010001038.5
SLQ-1501503.3050001200046508130252058401094266067916001185
Viscosity (OE)46.391244

SLQ Double Oil Grease Filter Dimensions

AVE Oil Air Lubrication Mixing Valve and Air Oil Divider Dimensions
ModelSize(DN)ABB1B2Cd1D3D4H
SLQ-3232140250186154344G3/8″145
SLQ-4040165265222184410180
SLQ-5050190165693G1/2″330280355
SLQ-6565200170713374300395
SLQ-8080220202830G3/4″374320500
SLQ-100100250202895442400610
SLQ-1251252602401200G1″755600640
SLQ-1501503002401200755600860
ModelH1LL1hFlange size of Inlet and Outlet
D1D2bdn
SLQ-32440397386201351007818184
SLQ-4051548044714511085
SLQ-50800102316012510020
SLQ-658601097180145120
SLQ-809901202195160135228
SLQ-10011901337215180155
SLQ-125127019553024521018524
SLQ-1501530195528024021023