Grease Solenoid Directional Valve DF/SV

Product: DF, SV Grease Solenoid Directional Valve 
Products Advantage:
1. 4/3 solenoid directional valve control
2. Max. pressure operation up to 20Mpa/200bar
3. Powerful solenoid and reliable valve, guaranty each switching action.

Equal Code With DF &SV:
– 34DF-L2 (SV-32)
– 23DF-L1 (SV-31)

Grease solenoid directional valve DF, SV series is used for electric terminal type centralized lubrication system, received the switching single from electric control box controlled by a pressure control valve in order to control the grease solenoid directional DF, SV valve to achieve the two oil main pipes in charge of the alternative grease supplying.

Grease solenoid directional valve DF, SV series is used of cylindrical structure, so that the valve opening and closing tightly, to maintain high pressure for a long time without leakage. The usage of powerful solenoid and spring buffer, making the action of switching much more reliable.

Working Principle Of Grease Solenoid Directional Valve DF/SV Series
Position 1:
Finished of supplying oil, solenoid “a” and solenoid “b” are in powered off.And demagnetization condition, oil inlet port closed, the lubrication pump not working. In this position, two main oil supply pipes are opened to the oil tank.

Position 2:
While starting the pump, the solenoid “a” power on and in a magnetization condition, the grease or oil from the pump output was transferred by the A port to the grease/oil main supply pipe L1, main pipe L2 is still open to the grease/oil reservoir.

Position 3:
The pressure control valve is installed at the end of main supply pipe, while the pressure at the end of the main pipe L1 exceeds the set pressure of the pressure control valve, pushing spool to the right position.

Position 4:
When the spool moves to the right position, pull the linkage with its contact head to the left, make the limit switch LS-1 in the connected state, sending signal to the control cabinet, in order the solenoid “a” power on, the pump stops working, comes back to S-1 position.
When the grease/oil feeding in the next time, the solenoid “b” power on, the grease/oil is transferred to main supply pipe L2 by B port, the pressure control valve controls the travel switch in the power off condition.

Grease-Solenoid-Directional-Valve-DFSV-function

Ordering Code Of Grease Solenoid Directional Valve DF/SV Series

HS-34DFL2*
(1)(2)(3)(4)(5)(6)(7)

(1) HS = By Hudsun Industry
(2) 3 = 3 Switching Postion
(3) 4 = 4 Way
(4) DF = Solenoid Directional Valve
(5) L= Max. pressure up to 20Mpa/200bar
(6) 2= Two outlet port
(7) * = For further information

Grease Solenoid Directional Valve DF/SV Series Technical Data

ModelMax.

Pressure

Flow RatePortReturn PortSwitch

Frequency

TemperatureWeight
CodeEqual
34DF-L2SV-3220Mpa3L/min410Mpa300-50℃17Kgs
23DF-L1SV-31310Kgs

Note:
1. The degree of penetration of the grease is 310 to 385 (NLGI0 # to # 1).
2. The pressure in the oil reservoir (return port pressure) can be used directly under 3Mpa. The external drain should be connected in the 3MPa ~ 10MPa.

DF/SV Solenoid Technical Data

PowerOutputCurrentVoltage FluctuationHumidityLoadingInsulation Grade
VoltageFrequencyValuePeak-15~10%0~95%100%H
AC220V50Hz~60Hz30W0.6A6.5A