Oil Grease Filters

//SLQ Double Oil Grease Filter For 6bar Lubrication Equipment

SLQ Double Oil Grease Filter For 6bar Lubrication Equipment

SLQ-Double-Oil-Grease-Filter

Product: SLQ Double Oil Grease Filter
Products Advantage:
1. Max. operation 6bar
2. Filtering area from 0.082cm2 ~3.30 cm2
3. Double tank for cycle filtering 24Hs working available

SLQ Double oil grease filter is suitable for the nominal pressure of 0.6MP in the oil lubrication system, with the removal of impurities in the lubricating oil to the lubrication point of the oil to achieve the clean function, small for the whole, the larger for the combination, respectively, by the two group filter cartridge and a three-way six-way valve composition, work a tube work, a tube backup, can be achieved without switching switch filter cartridge to achieve the purpose of continuous lubrication system.

SLQ Double Oil Grease Filter Working Principle:

  1. SLQ Double oil grease filter consists of a six-way valve and two groups of filter devices, placed in the pump outlet and cooler front, normal work, a group of filter device and the other group is closed by the valve as stand-by application.
  2. The valve-type six-way valve is the manual operation while the work process, cut off the standby filter device connected to the work of the filter device, the upper part of the valve, only the mark, in the work for pressure ≤ 6kgf / cm2 can be non-stop commutation.
  3. The filter device is designed as the two groups, a group of work, other is as spare part. In the work of the filter device needs to be cleaned when cleaning, you can start another set of spare filter device, without affecting the normal work of the host.
  4. The symbol of SLQ double oil grease filter:SLQ-Double-Oil-Grease-Filter-symbol

Instructions For Using Of SLQ Double Oil Grease Filter:

1. When the filter inlet and outlet pressure difference ≥ 0.5kgf / cm2, indicating that the filter device has been blocked by mechanical impurities, should be promptly cleaned or replace the filter, the filter cylinder should also be cleaned.
2. In the normal work of the filter, the difference pressure of inlet and outlet port should be ≤ 0.035mpa.

Ordering Code Of SLQ Oil Grease Filter Series

HS- SLQ 40 *
(1) (2) (3) (4)

(1) HS = By Hudsun Industry
(2) SLQ = SLQ Double Oil Grease Filter series
(3) Filter Size (See the chart below)
(4) For Further Information

SLQ Double Oil Grease Filter Technical Data

Model Size
DN
(mm)
Max.
Pressure
Filter
Area
(m2)
Kinematic Viscosity (cSt) Weight
(kg)
28 46 67 89 326
Filter Fineness (mm)
0.08 0.12 0.08 0.12 0.08 0.12 0.08 0.12 0.08 0.12
Filter Fineness (mm)
SLQ-32 32 0.6MPa 0.082 130 310 120 212 63 161 28.5 68.7 18.7 48.8 81.7
SLQ-40 40 0.21 330 790 305 540 160 384 72.3 175 48 125 115
SLQ-50 50 0.31 485 1160 447 793 250 565 106.5 256 69 160 203.8
SLQ-65 65 0.52 820 1960 760 1340 400 955 180 434 106 250 288
SLQ-80 80 0.833 1320 3100 1200 2150 630 1533 288 695 170 400 346
SLQ-100 100 1.31 1990 4750 1840 3230 1000 2310 436 1050 267 630 468
SLQ-125 125 2.20 3340 8000 3100 5420 1680 3890 730 1770 450 1000 1038.5
SLQ-150 150 3.30 5000 12000 4650 8130 2520 5840 1094 2660 679 1600 1185
Viscosity (OE) 4 6.3 9 12 44

SLQ Double Oil Grease Filter Dimensions

AVE Oil Air Lubrication Mixing Valve and Air Oil Divider Dimensions
Model Size(DN) A B B1 B2 C d1 D3 D4 H
SLQ-32 32 140 250 186 154 344 G3/8″ 145
SLQ-40 40 165 265 222 184 410 180
SLQ-50 50 190 165 693 G1/2″ 330 280 355
SLQ-65 65 200 170 713 374 300 395
SLQ-80 80 220 202 830 G3/4″ 374 320 500
SLQ-100 100 250 202 895 442 400 610
SLQ-125 125 260 240 1200 G1″ 755 600 640
SLQ-150 150 300 240 1200 755 600 860
Model H1 L L1 h Flange size of Inlet and Outlet
D1 D2 b d n
SLQ-32 440 397 386 20 135 100 78 18 18 4
SLQ-40 515 480 447 145 110 85
SLQ-50 800 1023 160 125 100 20
SLQ-65 860 1097 180 145 120
SLQ-80 990 1202 195 160 135 22 8
SLQ-100 1190 1337 215 180 155
SLQ-125 1270 1955 30 245 210 185 24
SLQ-150 1530 1955 280 240 210 23
2017-06-28T18:30:19+00:00