Progressive Divider Valve

//Progressive Divider Valve SSV8 – Single Line Lubricant Distributor, Distribution Valve

Progressive Divider Valve SSV8 – Single Line Lubricant Distributor, Distribution Valve

Progressive Valve SSV8

Product: SSV8 – Progressive Valve
Products Advantage:
1. High Quality Control: The inner connection holes processes by digital machines, precisely dimensions of the qualified items is much reliable for long distance lubrication spots.
2. Strictly Tested After Finishing: Using 32# or 46# mineral oil test, each product tests more than several minutes to confirm the function and leakage.
3. Surface Treatment: The surface treatment is by black oxidized surface to resist severe working conditions, like dust, mist even outdoor operation.

Progressive Valve SSV8 Introduction

Progressive valve SSV8 series is operated by progressive type, used for 300bar or 350bar single line grease or oil centralized lubrication system.

The working principle of progressive valve SSV8 is when the lubricant enters the metering device and flows to the right-hand end of piston, the piston is moved to the left under the pressure of the lubricant, causing the lubricant ahead of the left hand end of piston dispensed to outlet number 2. Once the piston has reached its left-hand final position, the junction channel to the right-hand end and the next piston is opened. The lubricant arrives from above also moves the next piston to the left, causing the lubricant quantity ahead of the left-hand end of piston to be dispensed to outlet number7, this is half a cycle of the SSV8 progressive valve.

Ordering Code Of Progressive Valve SSV8

SSV 6 / 8  / 10 / 12 / 14 /16 … *
(1) (2) (3) (4)

(1) SSV = Progressive divider valve SSV series
(2) Number Of Outlet= 6, 8, 10, 12, 14, 16, Or More …
(3) K = With indicator pin
(4) *  = Further information

Progressive Valve SSV8 Technical Data

Model
SSV8 Progressive Divider Valve
Raw Materials:
45# High strength carbon steel
Max. pressure
350bar / 5075psi
Min. pressure
20bar / 290psi
Output volume
0.2cm3/stoke
Connection tube size
4mm & 6mm
Working Pressure:
Max. operation pressure: 350bar/ 5075psi
Feed Line Threaded Connection:
G1/8

Minimum Order Quantity:
Please consult us
Surface Treatment:
Block galvanization or zinc plated
Package:
With strong box or cartons for exporting
Medium:
Use of media for cone penetration greater than 265 (25°C, 150g) 1/10mm, (NLGI0 # -2 #) with grease
Lubricants viscosity grade than N68
Trade Terms:
FOB, CFR, CIF, FAS, CIP, FCA, EXW
Delivery Time:
Depends on the quantity and standard or custom design, usually 10-25 working days
Place of Origin:
China

Progressive Valve SSV8 Working Principle

Lubrication-Divider-Valve-SSV-Working-principle

Stage one description:
The lubricant enters the metering device from above (white arrow) and flows to the right-hand end of piston A.
Piston A (black arrow) is moved to the left under the pressure of the lubricant, causing the lubricant ahead of the left hand end of piston A to be dispensed to outlet 2 (dashed arrow).

Stage two description:
Once piston A has reached its left-hand final position, the junction channel to the right-hand end of piston B is opened.
The lubricant which arrives from above (white arrow) also moves piston B (black arrow) to the left, causing the lubricant quantity ahead of the left-hand end of piston B to be dispensed to outlet 7 (dashed arrow).

Lubrication-Divider-Valve-SSV-Working-principle

Stage three description:
Once piston B has reached its left-hand final position, the junction channel to the right-hand end of piston A is opened.
The lubricant grease flows from above (white arrow) moves piston C (black arrow) to the left, causing the lubricant quantity ahead of the left-hand end of piston C to be dispensed to outlet 5 (dashed arrow).

Stage four description:
The channel to the right-hand end of piston D is now open (black arrow).
The lubricant grease is fed from above (white arrow) moves piston D to the left, causing the lubricant quantity ahead of the left-hand end of piston D to be dispensed out of the metering device via outlet 3 (dashed arrow).

Lubrication-Divider-Valve-SSV-Working-principle

Stage five description:
In phase 4, piston D had opened the junction channel to the left-hand end of piston A.
The lubricant flowing in (white arrow) moves piston A to the right (black arrow), causing the lubricant quantity to be dispensed to outlet 1(dashed arrow).
In the subsequent distribution sequence, pistons B – D are moved from the left to the right one after the other.
A complete distribution sequence is finished and a new cycle can begin.

Progressive Valve SSV8 Installation Dimensions

 

Model Dimension A (mm)
SSV 8 75

Progressive Valve SSV8 Connection Position


Note For Progressive Divider Valve SSV8:

1. We recommended using secondary stage
2. Only use the original spare parts, please contact us for replacement parts
3. The outlets 1 and 2 never be closed
4. It should begin from the lowest and highest outlets when changing fitting or tubes
5. Some outlets needed to be closed and combination the lubricants and sealed with plug M10x1 as per the drawing right.

2017-03-02T05:24:42+00:00