Metering Device - Dual Line Grease Lubricant Distributor

//Lubricating Device VSG4 – Grease Metering Device, Dual Line Lubricant Distributor

Lubricating Device VSG4 – Grease Metering Device, Dual Line Lubricant Distributor

Lubricating Device VSG4

Product: VSG4-KR Lubricating Device
Products Advantage:
1. High Quality: High strength carbon steel as main valve house, reaching the maximum operation pressure to 400bar/5800psi to each feed outlets.
2. Strictly Tested: Using 32# or 46# mineral oil tested, thinner than greasing oil. Guarantee lubricates the long distance lubrication spots completely, 100% tested for each valve.
3. Standard Dimensions: The standard industrial installation dimensions will be easily to replace and saving repair cost largely for annual overhaul of equipment.

Lubricating Device VSG4 Introduction

Lubricating device VSG4 is two line lubricating used for centralized lubrication system, with tow supplying grease or oil piping and four feeding outlets.

Lubricating device VSG4-KR is used of media for cone penetration of not less than 265 (25°C, 150g) 1/10mm grease (NLG I0 # ~ 2 #) or greater than the N68 lubricant viscosity grades , the use of ambient temperature is -10°C ~ 80°C ; such as the use of media for the oil , please use the 20MPa pressure. The two inlet ports are connecting with two supplying piping and two inlet ports are connected each, one should be blocked if not used like feeding oil outlets at certain time.

Dual-line- Lubricant -Distributor-Inner-structure

Ordering Code Of Lubricating Device VSG4

VSG 2 / 4  / 6 / 8 KR *
(1) (2) (3) (4)

(1) VSG = VSG series two line metering divider
(2) Number Of Discharging (Outlet Port)= 2 ports / 4 ports / 6 ports / 8 ports
(3) KR = With indicator pin and progressive adjustment
(4) *  = Further information

Lubricating Device VSG4 Technical Data

Model:
VSG 4-KR
Raw Materials:
45# High strength of carbon steel
Working Pressure:
Max. operation pressure: 400bar/ 5800psi
Min. pressure
35bar / 508psi
Output volume
0~2.2cm3/stoke, adjustable
Adjusting flow by each turn
0.14cm3
Main Line Threaded Connection:
G3/8
Feed Line Threaded Connection:
G1/4

Minimum Order Quantity:
Please consult us
Package:
With strong box or cartons for exporting
Medium:
For cone penetration of not less than 265 (25°C, 150g) 1/10mm grease (NLGI0 # ~ 2 #) or greater than the N68 lubricant viscosity grades
Items Delivery:
Depends on the quantity and standard or custom design, usually 8-25 working days
Surface Treatment:
Zinc plated for resistance of corrosion
Place of Origin:
China

Lubricating Device VSG4 Position of Lock Screw Condition

A – Lock screw
B – Rotary slide horizontal: 2 outlets
– Rotary slide vertical: 1 outlet
With the two main lines being relieved (i.e. when the pump is switched of) the lock screw A can be closed and the rotary slide B can be turned through 90°. If the rotary slide is put into position 1 the connecting passage between the two outlets is closed, and the lubricant is discharged by the two outlets. If the rotary slide is in position 2, the connecting passage is open. In this case one of the two outlets has to be closed by means of a closure plug, and then the double lubricant volume is discharged by the other outlet.

VSG-Two-Line-Metering-Device-Screw-Condition-Explanation

Lubricating Device VSG4 Working Operation Graphic

Pressurized lubricant is supplied to the metering device via main line I. The control piston (1) starts moving in the direction of arrow A, displacing the lubricant in front of the control piston into the relieved main line II.

Dual-line-divider-valves-working-operation-graphic-step-one

Dual-line-divider-valves-working-operation-graphic-step-two

When the control piston (1) uncovers the connecting passage (2) lubricant is transferred to the right end of the dispensing piston (3), thereby displacing it to the left in the direction of arrow A.
The lubricant volume ahead of the dispensing piston is transferred via the connection passage (4) to the lubrication point. With the dispensing piston in its terminal position, the pressure in main line I will continue to rise to reach the preset change-over pressure of the two-line system. At this stage,the change-over valve of the system operates to connect main line I which has so far been under pressure to the lubricant reservoir of the lubrication pump.

At the same time the change-over valve connects main line II to the lubrication pump, thus pressurizing the lubricant in this main line. The control piston (1) moves in the direction of arrow B, displacing the lubricant ahead of the control piston into the relieved main line I.

Dual-line-divider-valves-working-operation-graphic-step-three

Dual-line-divider-valves-working-operation-graphic-step-four

When the control piston (1) uncovers the connecting passage (5) lubricant is transferred to the left end of the dispensing piston (3) and displaces it to the right in the direction of arrow B. The lubricant ahead of the dispensing piston (3) is transferred via the connecting passage (6) to the lubrication point. With the dispensing piston (3) in its terminal position, the pressure in main line II will continue to rise to reach the preset changeover pressure of the two-line system. At this stage, the change-over valve will once again cause a pressure changing-over in main lines I and II and the cycle will be repeated as described in stage 1.

Lubricating Device VSG4 Output Volume Adjustment

Variation KR for infinitely variable adjustment and visual indication.Infinitely variable adjustment of lubricant output is achieved by turning the adjustment screw F. Maximum output is available if the lock screw E and the adjustment screw F are in their uppermost position. By turning the screw downward the output can be continuously reduced. With the two screws in their fully closed position, the indicator pin G is completely restrained and, because the pin is attached directly to the dispensing piston, the lubricant output will be nearly zero.
The indicator pin shows the correct functioning of a pair of outlets. After setting the lubricant output, the adjustment screw F will be locked in position by means of screw E.
To secure the setting, lock the adjusting screw only when the indicator pin is retracted.

VSL-divider-vavle-Output-volume-adjustment-method

Lubricating Device VSG4 Adjustment Curve

Dual-line-Lubricant-Distributor-operatation-curve

Lubricating Device VSG4 Installation Dimensions

Metering Device-Installation-dimensions
Model VSG 4-KR
Outer Ports 4
L1  (mm) 62
L  (mm) 76