Heat Exchangers

//SGLL Double Pipe Cooler, Heat Exchanger–Double Tube Type, Oil And Water Heat Exchanger, Cooler For Lubrication System

SGLL Double Pipe Cooler, Heat Exchanger–Double Tube Type, Oil And Water Heat Exchanger, Cooler For Lubrication System

FL Air Heat Exchanger

Product: SGLL Double Oil Cooler, Water Heat Exchanger 
Products Advantage:
1. Max. operation 1.6 Mpa
2. Big cooling area up to 12m2
3. Vertical and horizontal installation is available

The Working Conditions Of SGLL Double Oil Cooler
SGLL double oil cooler is designed and manufactured according to GB standard and reference to Germany AD and US TEMA Standard. All of the raw materials are steel and partial brass as construction, oil side working pressure with 1.6MPa, working temperature 150℃, water side working pressure 1.0MPa, working temperature 100℃. SGLL double oil cooler with energy saving, efficient, safe and reliable, etc .; for steam turbine, motor units, compressor units, fans, pumps and oil and oil industry on the oil cooling system can also be used for other oil cooling system.

The characteristics Of SGLL Double Oil Cooler
1. The tablet of data for the two flow tube double oil cooler, if you need to use four processes, six processes, bare tube or fin cooling tube cooler.
2. The cooler installation is usually horizontal, such as the user can need to use two vertical arrangement, a water chamber in the next, another water room in the room for easily remove.
3. Oil and water interface flange standard JB / T81-94, according to user requirements with non-standard flange should meet the piping requirements.
4. According to API 614 standard, the cooler with double structure, by the same area of two coolers and three-way valve device, a work, one prepared with each cooler capable of withstanding the cooling load of the entire system, with a tube plate fixed, a floating, removable tube bundle and a water chamber lid for easy operation, wash, check and repair. Cooler material, depending on the use of places, water system conditions can have a variety of options, water room, shell, three-way valve optional carbon steel or all stainless steel,
Tube board available carbon steel, stainless steel or brass plate; pipe material optional ordinary brass tube H68, arsenic brass tube H S n70-1A, aluminum brass tube H A177-2A, stainless steel pipe
1Cr18Ni9Ti, B10, B30 and so on.
5. Three-way valve with steel welded structure continuous flow switch valve. This valve in the internal structure of the failure or valve conversion period will not cause oil interruption. Shape as shown below.

Ordering Code Of SGLL Doulbe Tube Oil Cooler Series

HS- SGLL 4 12 / 1.6 V *
(1) (2) (3) (4) (5) (6) (7)

(1) HS = By Hudsun Industry
(2) SGLL = Double Pipe Oil Cooler
(3) Series Nos.  
(4) Cooling Surface Area (Check Chart Below)
(5) Max. Pressure: 1.6Mpa
(6) Installation Type: V= Vertical Installation; H= Horizontal Installation
(7) Further Information

SGLL Double Oil Cooler Horizontal Installation Dimensions

SGLL-horizontal -installation
Model Cooling Area
(m2)
DN1 DN2 D1 L L3 C H2 e L2 C1 C2 B H H1
SGLL4-12/1.6H 12 65 65 325 1555 660 860 262 870 497 345 300 370 984 460
SGLL4-16/1.6H 16 65 65 325 1960 1065 1365 262 870 497 345 300 370 98 460
SGLL4-20/1.6H 20 80 65 325 2370 1475 1775 262 870 497 345 300 370 1004 480
SGLL4-24/1.6H 24 80 65 325 2780 1885 2175 262 870 497 350 300 370 1004 480
SGLL4-28/1.6H 28 80 65 325 3190 2295 2585 262 870 497 350 300 370 1004 480
SGLL4-35/1.6H 35 100 100 426 2480 1232 1692 313 890 730 500 300 730 1181 555
SGLL5-40/1.6H 40 100 100 426 2750 1502 1962 313 890 730 500 300 730 1181 555
SGLL5-45/1.6H 45 125 100 426 3020 1772 2202 313 890 725 515 300 725 1181 585
SGLL5-50/1.6H 50 125 100 426 3290 2042 2472 313 976 725 515 300 725 1181 585
SGLL5-60/1.6H 60 125 100 426 3830 2582 3012 313 976 725 515 300 725 1181 585
SGLL6-80/1.6H 80 200 200 616 3160 1555 2015 434 1100 935 700 750 935 1688 820
SGLL6-100/1.6H 100 200 200 616 3760 2155 2615 434 1240 935 700 750 935 1688 820
SGLL6-120/1.6H 120 200 200 616 4360 2755 3215 434 1240 935 700 750 935 1688 820

SGLL Double Oil Cooler Vertical Installation Dimensions

SGLL-horizontal -installation
Model Cooling Area
(m2)
a b c d e f g m o d3 D DN1 DN2
SGLL4-12/1.6V 12 1555 960 870 320 520 475 340 120 80 8-Φ26 325 65 65
SGLL4-16/1.6V 16 1960 1365 870 320 520 475 340 120 80 8-Φ26 325 65 65
SGLL4-20/1.6V 20 2370 1775 870 320 565 475 340 120 80 8-Φ26 325 80 65
SGLL4-24/1.6V 24 2780 2175 870 340 565 475 360 120 80 8-Φ26 325 80 65
SGLL4-28/1.6V 28 3190 2585 870 340 565 475 360 120 80 8-Φ26 325 80 65
SGLL5-35/1.6V 35 2610 1692 976 470 666 585 400 120 80 8-Φ26 426 100 100
SGLL5-40/1.6V 40 2880 1962 976 470 726 585 400 120 80 8-Φ26 426 100 100
SGLL5-45/1.6V 45 3120 2202 973 470 726 585 420 120 80 8-Φ26 426 125 100
SGLL5-50/1.6V 50 3390 2472 1100 470 726 585 420 140 100 8-Φ26 426 125 100
SGLL5-60/1.6V 60 3930 3012 1240 470 990 585 420 140 100 8-Φ26 426 125 100
SGLL6-80/1.6V 80 3255 2015 1240 705 990 830 460 140 100 8-Φ30 616 200 200
SGLL6-100/1.6V 100 3855 2615 1346 705 1066 830 460 140 100 8-Φ30 616 200 200
SGLL6-120/1.6V 120 4455 3215 1346 705 1066 830 460 140 100 8-Φ30 616 200 200